Conductivity Detector
New!
Microprocessor-based LC Detector for Ionic Species

- Turns any HPLC into an Ion
Chromatograph
- High Sensitivity Detection
of all Charged Species
- Temperature-Controlled
Cell for Stable Baselines
- Suitable for
Suppressor-Based and Single-Column IC
The Best
Detector for Ion Analysis
Turn your HPLC System into a
High-Sensitivity Ion Chromatograph!
The Conductivity Detector provides
universal, reproducible, high-sensitivity detection of all
charged species. Use your HPLC system with the Conductivity
Detector for simple, reliable, and inexpensive quantification of
anions, cations, metals, organic acids, and surfactants down to
ppb level.

| Microprocessor-Based
for High Sensitivity and Extended Linearity The new advanced
microprocessor-based circuit improves detection
sensitivity by reducing baseline noise and drift. Linear
response extends over a wide range of analyte
concentrations.
|
 |
| Temperature-Controlled
Cell for Stable, Drift-Free Baselines Temperature fluctuations cause
baseline noise and drift with other conductivity
detectors. The temperature-controlled cell and heat
exchanger are isolated from external temperature changes
for stable baselines. Adjust or monitor cell temperature
(ambient - 80º C) easily from the detector's front
panel.
|
 |
| Works
with any IC Method The digital autozero in the Conductivity
Detector offsets high conductivity eluants (up to 10,000
µS/cm) within 5 seconds, for detection with
single-column or suppressor-based methods. Other
detectors designed for suppressor-based IC systems are
unable to offset the high conductivity eluants used in
SCIC.
|
 |
Easy to Use, Troubleshoot,
and Maintain
The Conductivity Detector makes IC
analysis easier and more reliable. An intuitive membrane
key-panel controls all detector functions. Three working modes
(CALIBRATE, BACKGROUND, and MEASURE) let you check detector
electronics, red the eluant's absolute conductivity, or perform
analyses, respectively. Use the CALIBRATE mode to check the
detector's calibration and gain for compliance with ISO-9000,
GLP, or GMP programs. Use the BACKGROUND mode to check the
quality and accuracy of the eluant. The large LED display shows
detector signal, background conductance, cell temperature, or
cell temperature set point. Two keys allow you to set range from
0.1 to 5000 µS/cm or cell temperature from ambient to 80º C. An
RS-232 serial port provides digital communication and control via
an external computer.
CONDUCTIVITY DETECTOR
SPECIFICATIONS
|
| Type: |
Alternating
current, Synchronous Detection, 10 kHz Frequency |
| Range: |
0.1-5000 m S/cm
(DI water, 1 mL/min., 35° C) |
| Noise: |
<
0.0025 m S/cm (DI water, 1 mL/min., 35° C) |
| Drift: |
< 0.03 m
S/cm/hr (DI water, 1 mL/min., 35° C) |
| Digital
autozero: |
Offsets
up to 10,000 m S/cm |
| Cell Type: |
2 electrode, 0.5 m L volume, gold-plated stainless-steel
electrodes |
| Display: |
4-digit
LED in 6 modes Working
Modes:
a. Calibrate: test reading of 100 m S/cm, with 10-step gain test
b. Background: absolute conductivity of eluant
c. Measure: conductivity of eluant with background
offset
Display Modes:
a. Conductivity in m S/cm
b. Temperature: actual cell temperature in ° C
c. Temperature set: cell temperature set
point in ° C
|
| Analog Signal Output: |
10 mV and 1V FS, switch-selectable |
| Digital
Communications: |
RS-232
output of detector signal, external set of detector
functions |
| Time Constant: |
Fast or Slow, switch-selectable |
CELL COMPARTMENT
|
| Insulation: |
Minimum
1 inch all sides |
| Heater: |
45W DC heating element vulcanized
to aluminum block |
| Size: |
2.7"
W x 2.45" H x 6.2" L |
| Temperature: |
Factory-set at 35° C; User-adjustable ambient to 80° C |
| Overtemp
Protection: |
Factory-set
at 60° C; User-adjustable |
| Precision: |
± 0.05° C |
| Heat
Exchanger: |
TFE
tubing knitted and encased in high thermal-mass housing |
ELECTRICAL/ELECTRONIC
|
| Power: |
110/120
Vac, 50/60 Hz (field-selectable) |
| Data: |
Analog output, 0-1 Vdc or 0-10 mVdc
(selectable) |
| Computer
Interface: |
RS-232
serial communications |
FLUID PATH
|
| Construction: |
All
wetted parts are inert polymers: PEEK (polyetherether
ketone), and TeflonÒ |
FRONT PANEL FUNCTIONS

| COND |
Displays
conductivity in m S/cm |
| MEASURE |
Displays
conductivity with background subtracted |
| BACKGROUND |
Displays
absolute conductivity with no offset |
| CALIBRATE |
Checks
gain and calibration of detector electronics |
| TEMP |
Displays
actual cell temperature |
| TEMP
SET |
Displays
cell temperature set point. Adjust by using the UP and
DOWN arrow keys. |
| AUTOZERO |
Digitally
offsets the background conductivity while in the MEASURE
mode |
| UP
and DOWN arrows |
Select
the range in the COND mode or the cell temperature set
point while in the TEMP SET mode |
CONDUCTIVITY DETECTOR
Features and Benefits
| Feature |
Benefit |
| Convenience
and Reliability |
|
| Tactile
membrane front panel |
Simple,
intuitive control of all detector functions |
| Internal calibration |
Verifies electronic calibration and
gain for ISO-9000, GLP, and GMP compliance |
| Background
mode |
Measures
eluant's absolute conductivity for quick troubleshooting |
| Read and set cell temperature from
the front panel |
Fast, easy adjustment and
verification of cell temperature |
| Remote
operation of detector functions or digital transmission
of detector signal via RS-232 |
Operate
the detector of collect data with an external computer |
| Performance |
|
| Microprocessor-based |
Low noise and drift for higher
sensitivity, wide dynamic range, and fast, digital
autozero |
| Temperature-controlled
cell housing with built-in heat exchanger |
Stable
baselines, even at high sensitivity ranges |
| Digital autozero |
Offsets high-conductivity eluants
for compatibility with single-column or suppressor-based
methods |
| Synchronous
AC detection |
Simple
two-electrode cell for high reliability and low
maintenance |
| Versatility |
|
| Compact modular design |
Adds IC capability to any existing
HPLC system |
| Electronic
offset of high-conductivity or low-conductivity eluants |
Works
with both single-column and suppressor-based methods |
Ordering information
| Part No. |
Description |
| AL5500 |
Conductivity Detector |
| AL3351 |
Chemical suppressor
module for Conductivity Detector |
| AL-535100 |
Eris 1000™
Autosuppressor |
Return to
Detector Home Page

click here to return to the home page
|